DGM Series Air driven liquid pump

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Guangdong
Validity to: Long-term effective
Last update: 2018-05-15 20:12
Browse the number: 297
inquiry
Company Profile
 
 
Product details
DGM Series Air driven water/liquid/ hydraulic pump


Suncenter Compressed Air Driven Liquid Booster Pump-DGM Series

We offer the most complete range of Air driven liquid pump models in the industry measured for:

A.Capability of ultimate pressure, flow or output horsepower. 

B.Compatibility with a broad variety of liquids, such as oil, water and chemical applications.


SUNCENTER pumps are air driven at a drive air pressure of 2 to 10bar (29 to145 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.

Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.


SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator. The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. SUNCENTER liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don’t reduce the indicated port sizes and consult SUNCENTER for exact flow conditions not shown in charts.


Applications include:


·Pressure testing

·Burst(Hydrostatic) testing

·Work holding/power clamping

·Jacking/lifting

·Valve actuator control

·Hydraulic cylinder actuation

·Press safety overload devices

·Roller tensioning

·Metering

·Precision lubrication and spraying

·Liquefied gas transfer


Key features include: 

·Compressed Air driven - no electricity required (connect to normal air compressor)

·In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

·No airline lubricator required 

·Pressures to 640Mpa (6400 bar)  

·Wide range of models with different ratios

·Built-in-cooling on most models 

·Easy to install, operate and maintain

·Best price / performance ratio 

·No heat, flame or spark risk and explosion proof 

·Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant


DGM Series Liquid Pumps(Single acting, single air drive head)

·They have aluminum bodies, with oxidation treatment and wetted materials of carbon steel or stainless steel, which depending on different service liquid. Material of stainless steel, making them an excellent choice of water application.

·Portable design.

·High quality seals, long service life available

·Easy to install, operate and maintenance.

·Explosion proof and no electrical power required.



Model

Pressure  Boost Ratio

Driven air pressure P

Formula to calculate outlet pressure

MAX Outlet
Pressure

Liquid inlet Connection

Liquid outlet Connection

MaxFlow rate(L/min)**

DGM1

1:1

3-8 bar

1XPL

8 bar

NPT1

NPT1/2

20.50

DGM4

4:1

3-8 bar

4XPL

32 bar

NPT1

NPT1/2

15.36

DGM10

10:1

3-8 bar

10XPL

80 bar

NPT3/4

NPT1/2

7.15

DGM16

16:1

3-8 bar

16XPL

128 bar

NPT /2

NPT 1/2

4.59

DGM30

30:1

3-8 bar

30XPL

240 bar

NPT 1/2

NPT 3/8

2.53

DGM44

44:1

3-8 bar

44XPL

352 bar

NPT 3/8

NPT 3/8

1.41

DGM64

64:1

3-8 bar

64XPL

512 bar

NPT 3/8

NPT 3/8

0.95

DGM100

100:1

3-8 bar

100XPL

800 bar

NPT 3/8

NPT 3/8

0.64

DGM170

170:1

3-8 bar

170XPL

1360 bar

NPT 3/8

M14*1.5

0.37

Should the dgm series high pressure liquid pump caters to your requirement, welcome to buy the equipment with our factory. Well-known as one of the professional manufacturers and suppliers, we're equipped with a productive factory to produce the best quality equipment for you.

http://www.suncentergroup.com/

Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]